martes, 10 de febrero de 2015

Ventilación difícil con mascarilla facial/Difficult mask ventilation

Nuevo portal / New website

Ya pueden visitar nuestro nuevo portal anestesia-dolor.org. Seguiremos trabajando por una mejor educación virtual.
You can now visit our new website anestesia-dolor.org . We will continue working for a better virtual education.
Ventilación difícil con mascarilla facial en la población general de cirugía: observación de los factores de riesgo y los factores predictivos
Difficult mask ventilation in general surgical population: observation of risk factors and predictors.
Cattano D1, Killoran PV1, Cai C2, Katsiampoura AD1, Corso RM3, Hagberg CA1.
F1000Res. 2014 Aug 27;3:204. doi: 10.12688/f1000research.5131.1. eCollection 2014.
Abstract
BACKGROUND: There are few predictors of difficult mask ventilation and a simple, objective, predictive system to identify patients at risk of difficult mask ventilation does not currently exist. We present a retrospective - subgroup analysis aimed at identifying predictive factors for difficult mask ventilation (DMV) in patients undergoing pre-operative airway assessment before elective surgery at a major teaching hospital. METHODS: Data for this retrospective analysis were derived from a database of airway assessments, management plans, and outcomes that were collected prospectively from August 2008 to May 2010 at a Level 1 academic trauma center. Patients were stratified into two groups based on the difficulty of mask ventilation and the cohorts were analyzed using univariate analysis and stepwise selection method.
RESULTS: A total of 1399 pre-operative assessments were completed with documentation stating that mask ventilation was attempted. Of those 1399, 124 (8.9%) patients were found to be difficult to mask ventilate. A comparison of patients with and without difficult mask ventilation identified seven risk factors for DMV: age, body mass index (BMI), neck circumference, history of difficult intubation, presence of facial hair, perceived short neck and obstructive sleep apnea. Although seven risk factors were identified, no individual subject had more than four risk factors. CONCLUSION: The results of this study confirm that in a real world clinical setting, the incidence of DMV is not negligible and suggest the use of a simple bedside predictive score to improve the accuracy of DMV prediction, thereby improving patient safety. Further prospective studies to validate this score would be useful.
PDF 
Atentamente
Anestesia y Medicina del Dolor

No hay comentarios: